Servo motor heat staking welding machine

servo motor heat staking welding machine, it is the role of the heat staking welding head heated over, using the motor down pressure to let the welding unit with the maximum pressure to make the product welding column (tendons) to form a certain shape, while using the pre-pressure unit to press the upper and lower products, so that the two products weld together, while using the blow up cooling, so that the product riveted to form a saturated state to achieve a certain pressure.

Loading and unloading station Operator manual activities.

*load individual parts.

*Push the start button.

*Observe the device controller on the right side of the operator’s table.

*After welding is complete, unload the entire welded part.

servo heat staking welding equipment
servo heat staking welding equipment

Safety and Protective Device

Safety devices are part of the normal servo motor heat staking welding equipment condition they are used to protect human life and health safety, if make the safety device failure, then cannot prevent from acting carelessly and having fault.

Safety Circuit

The servo motor heat staking welding machine is equipped with the following safety circuits.

  1. Maintenance door Safety switch
  2. Emergency stop button at the operator’s position, distributed on the right side of the operator’s desk and the man-machine interface operation
  3. Safety curtain at operator’s position
  4. safety door from the operator side

Drive unit 

Pneumatic drive unit injury/extrusion hazard. Risk of extrusion between upper and lower dies. Danger of tool feed motion.

Upper drive unit

Vertical movement: The main cylinder moves the hot riveting unit up and down by driving the fixed plate of the hot riveting unit. The cylinder has a safety lock function.

Servo motor heat staking welding Equipment movement flow

1.Load parts

2.Press start button

3. Servo motor move down

4.Heat staking welding unit welding, welding completed servo motor up

5.Unloading, and repeat the above operation

Supply and Exhaust Connection

Electrical connections:

  • Wrong connection will cause the servo motor heat staking welding equipment to start up unexpectedly or fail to control the heat staking welding machine during
  • Mixed wiring may affect the service life of the
  • Wrong wiring will affect the service life of electrical

Compressed air connection

  • Check whether the compressed air hose is connected to the maintenance unit and whether the position is fixed.
  • The manual switch valve shall be opened for
  • Check whether the working pressure of the pressure indicator is 6

Front view of the servo motor heat staking welding machine

device operating/display elements

Hot riveting machine
Hot riveting machine

position

Description

1

Three-color indicator

2

Waterproof socket

3

Touch screen

4

Emergency stop button

5

Power switch

6

Control button

7

Stop button

8

Start button

When placing servo motor heat staking welding machine, attention:

 

  • Keep the perimeter of the servo motor heat staking welding machine at all angles, and the door at the entrance can be
  • All required operating stations are adequately
  • Place no
  • The conveyor has enough space to supply the raw materials and transport the
  • Connect the specified connection cable to ensure that there is no risk of
  • Power ground is safe and secure;
  • Please put a safe post in a reasonable position;
  • Check whether it’s solid of three-color lights before start machine;
  • Touch screen protection;
  • Make a device checklist and hang it on the device.

The servo motor heat staking welding machine shall be placed on a supporting foundation which is flat and capable of withstanding the weight of the heat staking welding equipment.

Before placing the Hot Riveting Machine and components, ensure that the foundation absorbs static and dynamic loads.

Place the Heat Staking Machine flat after placement.

Use the leveling feet to adjust the hot riveting welding machine to a higher level, the hot riveting welding machine should be placed horizontally. Fix the pedal pad which is djustable to the ground.

Troubleshooting

ID

Alarm text

Alarm action content

1

Emergency stop button is

pressed

Emergency stop button is pressed Switch to I/O screen to check if I0.0 is

normal Press reset to recover after troubleshooting

2

Side        safety door

malfunction

Check if the side safety is closed. Switch to I/O screen to check if I0.2 is

normal.

 

3

Front    vertical            grating failure

The front vertical raster is blocked. Switch to I/O screen to check if I0.3 is

normal. Check the fault and remove the alarm by activating the button or resetting.

4

Rear safety door failure

Check if the rear safety is closed. Switch to the I/O screen to check if I0.1

is normal.

5

Servo failure

Servo fault Troubleshooting according to the fault code The alarm can be

eliminated by the reset button after troubleshooting

6

Servo power not turned

on

Servo power is not turned on Turn on the servo power to eliminate the

alarm by the reset button after troubleshooting

7

Air pressure alarm

Air pressure is too low Check if air is ventilated or turn on the air supply

switch.

8

Stop button malfunction

Stop button is pressed Switch to I/O screen to check if I0.7 is normal Press

reset to restore after troubleshooting

9

Recipe mold mismatch

Mold recipe error Open mold management Check if the recipe number and

recipe name are correct

10

Pause in progress

Vertical raster is blocked during operation Press the start button under

operation to continue

11

Upper mold servo is not

in the original position

Servo fault Troubleshoot according to the fault code Eliminate the alarm

by resetting the button after the fault is solved

12

Blow 1 is not reset

Switch to automatic mode Switch to Balluff master station to check if

Q13.5 is normal Press reset to recover after troubleshooting

13

Blow 2 is not reset

Switch to automatic mode Switch to Balluff main station to check if Q13.6

is normal Press reset to recover after troubleshooting

14

Temperature of 1# rivet

head is abnormal

Check if the temperature setting is correct Check the heating line problem

15

2#Rivet head temperature

abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

16

3#Rivet head temperature

abnormality

Detect whether the temperature setting is correct and check the heating

circuit problem

17

4#Rivet head temperature

abnormal

Check whether the temperature setting is correct.

18

5#Rivet head temperature

abnormality

Detect whether the temperature setting is correct.

19

6#Rivet head temperature

abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

20

7#Rivet head temperature

Checking whether the temperature setting is correct and troubleshooting

 

 

ID

Alarm text

Alarm action content

 

abnormality

the heating circuit

21

8#Rivet head temperature

abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

22

9#Rivet head temperature

abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

23

10#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

24

11#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

25

12#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

26

13#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

27

14#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

28

15#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

29

16#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

30

17#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

31

18#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

32

19#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

33

20#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

34

21#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

35

22#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

36

23#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

37

24#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

38

25#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

39

26#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

40

27#Rivet                         head

temperature abnormal

Checking whether the temperature setting is correct and troubleshooting

the heating circuit

41

28#Rivet                         head

Checking whether the temperature setting is correct and troubleshooting