Jfortune Plastic Welding Machine: We help you integrate the best supply chain, design the most suitable technical solution, and avoid every pitfall we’ve already experienced.

hot plate plastic welding machine

Servo hot plate plastic welding machine, which serves to heat the surface of the individual components to be connected in the desired welding area and plasticize them. Subsequently the two separate components are extruded and welded by a vertical upper tool and a lower lift table. The hot plate plastic welding machine has an upper tool and a lower tool in which the respective components are fixed.hot plate welding machine manufacturer

Safety and Protective Device

The safety device is part of the hot plate plastic welding machine status. They serve to protect life, health and safety. If the safety device fails, the action is careless and faulty.

  • Safety Circuit

The hot plate plastic welding machine is fitted with the following safety circuits:

  1. Access door safety switch
  2. Emergency stop button for operator’s position, distributed below the operator’s table and HMI operation panel.
  3. Safety grating at operator’s position.

1

Safety Switch Behind Access door

2

stop button/ Emergency stop button

3

Safety grating

Transmission Unit (Actuating Device)

Risk of damaging/extruding the transmission unit Risk of squeezing between the upper and lower dies Risk of die feeding movement

  • Horizontal Transmission Unit

Horizontal movement: through reducer, the servo motor transmits the power to the gear rack mechanism to drive the hot die sliding table to move horizontally. The gear rack transmission is characterized by high load bearing and high transmission precision.

1

FE- horizontal movement

2

Linear slide rail locating

3

Hot die baseplate

4

Gear rack mechanism

5

Servo motor and reducer

hot plate welding equipment
hot plate welding equipment
  • Lower drive unit

Vertical movement: cylinder-driven lower cold tool slide moves in vertical direction, guided by linear bearings, with high guiding accuracy.

1

Vertical direction

2

Lower cooling tool base plate

3

Lower cooling tool cylinder

hot plate welding machine manufacturers
hot plate welding machine manufacturers
  • Upper drive unit

Vertical movement: cylinder-driven upper cold tool slide moves in vertical direction, guided by linear bearings, with high guiding accuracy.

1

Vertical direction

2

Upper cooling tool base plate

3

Upper cooling tool cylinder

4

Linear bearing

hot plate welding
hot plate welding

Troubleshooting of hot plate plastic welding machine

 

No.

Alarm Name/Description

Corrective Action

 

 

 

1

Emergency stop fault

1.Pull back the E-stop button, press down the fault reset button and alarm will be cleared 2.Check the E-stop safety relay signal I0.0 in I/O Input screen(green light should be on in normal condition)and fault resetI2.3(green

light should be on after button being pressed)

 

 

 

2

 

 

 

Door safety relay fault

1. Close the door, press down the fault reset button and alarm will be cleared

2. Check the E-stop safety relay signal I0.1 in I/O Input screen(green light should be on in normal condition)and fault resetI2.3(green

light should be on after button being pressed)

 

 

 

3

 

 

 

Safety light curtain fault

1. Check if the safety light curtain is being interrupted

2. Check the safety light curtain signal I0.2 in I/O input screen(signal light should be on in normal condition)

3. Check if the safety light curtain is damaged

4. Check the wiring

 

 

 

 

4

 

 

 

 

Upper tool servo fault

1. Press down Fault Rest button, clear the alarm

2. Check the error code displayed in the servo driver in the electric box, and read the servo manual to see the solution

3. Check the upper tool alarm signal I0.3 in I/O Input screen(signal light should be off in

normal condition)

 

 

 

 

5

 

 

 

 

Lower tool servo fault

1. Press down Fault Rest button, clear the alarm

2. Check the error code displayed in the servo driver in the electric box, and read the servo manual to see the solution

3. Check the lower tool alarm signal I0.4 in I/O

Input screen(signal light should be off in normal condition)

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

 

6

 

 

 

 

Hot tool servo fault

1. Press down Fault Rest button, clear the alarm

2. Check the error code displayed in the servo driver in the electric box, and read the servo manual to see the solution

3. Check the hot tool alarm signal I0.5 in I/O

Input screen(signal light should be off in normal condition)

 

 

7

 

 

Front left do closed

1. Close front left door

2. Check the front left door signal I1.1 in the I/O Input screen(green light should be on in

normal condition)

 

 

8

 

 

Rear left do closed

1. Close rear left door

2. Check the rear left door signal I1.2 in the I/O Input screen(green light should be on in normal condition)

 

 

9

 

 

Front right do closed

1. Close front right door

2. Check the front right door signal I1.5 in the I/O Input screen(green light should be on in normal condition)

 

 

10

 

 

Rear right do closed

1. Close rear right door

2. Check the rear right left door signal I1.6 in the I/O Input screen(green light should be on in normal condition)

 

 

11

 

 

HMI E-stop button being pressed

1. Pull back the E-stop button on HMI and alarm will be cleared

2. Check the HMI E-stop signal I1.0 in I/O Input screen(green light on – button being pressed;

green light off – button being pulled back)

 

 

12

 

 

LH E-stop button being pressed

1. Pull back the LH E-stop button and alarm will be cleared

2. Check the LH E-stop signal I1.1 in I/O Input screen(green light on – button being pressed;

green light off – button being pulled back)

 

 

13

 

 

RH E-stop button being pressed

1. Pull back the RH E-stop button and alarm will be cleared

2. Check the RH E-stop signal I1.2 in I/O Input screen(green light on – button being pressed;

green light off – button being pulled back)

 

14

 

Hot tool not rest

Move the hot tool to home position in

automatic mode before running the automatic cycle

 

 

No.

Alarm Name/Description

Corrective Action

 

15

 

Temperature 1 abnormal

Turn on the power of heating, raise the zone 1

temperature to allowed range and alarm will be cleared

 

16

 

Temperature 2 abnormal

Turn on the power of heating, raise the zone 2 temperature to allowed range and alarm will

be cleared

 

 

 

17

 

 

 

Upper tool not in home position

With no other alarms exist, switch to manual mode and press down the fault reset button. OR

Enter the home position parameters setting screen, move the upper tool back to home

position manually.

 

 

 

18

 

 

 

Lower tool not in home position

With no other alarms exist, switch to manual mode and press down the fault reset button. OR

Enter the home position parameters setting screen, move the lower tool back to home

position manually.

 

 

 

 

19

 

 

 

 

Hot tool not in home position

With no other alarms exist, switch to manual mode and press down the fault reset button. After upper and lower tool move back to home position, hot tool starts to reset.

OR

Enter the home position parameters setting screen, move the lower tool back to home position manually when upper and lower tools are in home position.

20

Upper part not unloaded

Unload the part from upper tool and alarm will

be cleared.

21

Lower part not unloaded

Unload the part from lower tool and alarm will

be cleared.

 

 

22

 

 

Incorrect recipe

1. Check if the harting plug is correctly connected

2. Check if the correct recipe is selected 3.Check if the wiring in the harting plug is

correct

23

Heating is on during tool change

Turn off the power of heating and alarm will be

cleared

 

 

24

 

 

Temperature 3 abnormal

Turn on the power of heating, raise the temperature of zone 3 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

No.

Alarm Name/Description

Corrective Action

 

 

25

 

 

Temperature 4 abnormal

Turn on the power of heating, raise the temperature of zone 4 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

26

 

 

Temperature 5 abnormal

Turn on the power of heating, raise the temperature of zone 5 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

27

 

 

Temperature 6 abnormal

Turn on the power of heating, raise the temperature of zone 6 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

28

 

 

Temperature 7 abnormal

Turn on the power of heating, raise the temperature of zone 7 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

29

 

 

Temperature 8 abnormal

Turn on the power of heating, raise the temperature of zone 8 to the allowed range(not exceed the limit) and alarm will be

cleared

 

 

 

30

 

 

 

Insufficient air pressure

1.  Check if the main air source is connected to the air hose

2.  Check if the emergency stop is pressed. If it is pressed, pull out the emergency stop and press the fault reset button to restore the air

supply

 

 

 

31

 

 

 

Upper fixture not clamped 1

1.Check whether the air supply is sufficient 2.Check the upper fixture 1 signal Q4.0 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

32

 

 

Tool lifter not in work position, please move the tool lifter to work position

1. Check if the tool lifter is in wort position.

2. Check if the proximity switch is detected.

3.  Check if the proximity switch is damaged or not.

4. Check the wiring

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

33

 

 

 

Upper fixture not clamped 2

1.Check whether the air supply is sufficient 2.Check the upper fixture 2 signal Q4.2 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

34

 

 

 

Upper fixture not clamped 3

1.Check whether the air supply is sufficient 2.Check the upper fixture 3 signal Q4.4 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

35

 

 

 

Upper fixture not clamped 4

1.Check whether the air supply is sufficient 2.Check the upper fixture 4 signal Q4.6 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

38

 

 

 

Lower fixture not clamped 1

1.Check whether the air supply is sufficient 2.Check the lower fixture 1 signal Q6.0 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

39

 

 

 

Lower fixture not clamped 2

1.Check whether the air supply is sufficient 2.Check the lower fixture 2 signal Q6.2 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

40

 

 

 

Lower fixture not clamped 3

1.Check whether the air supply is sufficient 2.Check the lower fixture 3 signal Q6.4 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

41

 

 

 

Lower fixture not clamped 4

1.Check whether the air supply is sufficient 2.Check the lower fixture 4 signal Q6.6 in I/O Output screen(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

44

 

 

Upper left safety lock not in home position

1. Check the magnetic switch of the upper left safety lock

2. If the signal light is on, check the upper left safety lock home position signal I7.0 in I/O Input screen; if signal is off, then check the

wiring.

 

 

 

45

 

 

Upper right safety lock not in home position

1. Check the magnetic switch of the upper right safety lock

2. If the signal light is on, check the upper right safety lock home position signal I7.1 in I/O Input screen;if signal is off, then check the

wiring.

 

46

Hot tool not in home position, please move hot tool to home position

Move the hot tool back to home position, alarm will then be cleared

 

47

Upper tool not in home position, please move upper tool to home position

Move the upper tool to home position, alarm will then be cleared

 

 

 

48

 

 

 

Temperature 1 exceeds the limit

Temperature in zone 1 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

49

 

 

 

Temperature 2 exceeds the limit

Temperature in zone 2 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

50

 

 

 

Temperature 3 exceeds the limit

Temperature in zone 3 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

51

 

 

 

Temperature 4 exceeds the limit

Temperature in zone 4 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

52

 

 

 

Temperature 5 exceeds the limit

Temperature in zone 5 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

53

 

 

 

Temperature 6 exceeds the limit

Temperature in zone 6 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

54

 

 

 

Temperature 7 exceeds the limit

Temperature in zone 7 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

55

 

 

 

Temperature 8 exceeds the limit

Temperature in zone 8 exceeds the limit. 1.Check whether the temperature setting is reasonable

2. Check the wiring

3. Check if the temperature module is damaged

 

 

 

56

 

 

 

Upper fixture not released after melting 1

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the upper fixture 1 home position

signal Q4.1 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

57

 

 

 

Upper fixture not released after melting 2

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the upper fixture 2 home position

signal Q4.3 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

58

 

 

 

Upper fixture not released after melting 3

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the upper fixture 3 home position

signal Q4.5 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

59

 

 

 

Upper fixture not released after melting 4

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the upper fixture 4 home position

signal Q4.7 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

62

 

 

 

Lower fixture not released after melting 1

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the lower fixture 1 home position

signal Q6.1 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

63

 

 

 

Lower fixture not released after melting 2

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the lower fixture 2 home position

signal Q6.3 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

64

 

 

 

Lower fixture not released after melting 3

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the lower fixture 3 home position

signal Q6.5 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

65

 

 

 

Lower fixture not released after melting 4

Select ‘Fixture release after melting 1.Check whether the air supply is sufficient 2.Check the lower fixture 4 home position

signal Q6.7 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

68

 

 

Upper fixture not released after sealing 1

1.Check whether the air supply is sufficient 2.Check the upper fixture 1 home position signal Q4.1 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

69

 

 

Upper fixture not released after sealing 2

1.Check whether the air supply is sufficient 2.Check the upper fixture 2 home position signal Q4.3 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

70

 

 

Upper fixture not released after sealing 3

1.Check whether the air supply is sufficient 2.Check the upper fixture 3 home position signal Q4.5 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

71

 

 

Upper fixture not released after sealing 4

1.Check whether the air supply is sufficient 2.Check the upper fixture 4 home position signal Q4.7 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

74

 

 

Lower fixture not released after sealing 1

1.Check whether the air supply is sufficient 2.Check the lower fixture 1 home position signal Q6.1 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

75

 

 

Lower fixture not released after sealing 2

1.Check whether the air supply is sufficient 2.Check the lower fixture 2 home position signal Q6.3 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

76

 

 

Lower fixture not released after sealing 3

1.Check whether the air supply is sufficient 2.Check the lower fixture 3 home position signal Q6.5 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

No.

Alarm Name/Description

Corrective Action

 

 

 

77

 

 

Lower fixture not released after sealing 4

1.Check whether the air supply is sufficient 2.Check the lower fixture 4 home position signal Q6.7 in I/O Output(green light should be on if powered up)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

80

 

 

Upper tool not in home position

When the hot tool moves, the upper tool does not reach the safe opening distance. Reset the upper tool to the safe opening distance to

clear the alarm

 

 

81

 

 

Lower tool not in home position

When the hot tool moves, the lower tool does not reach the safe opening distance. Reset the lower tool to the safe opening distance to clear

the alarm

 

84

 

Upper heating tube alarm H1-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

85

 

Upper heating tube alarm H1-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

86

 

Upper heating tube alarm H1-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

87

 

Upper heating tube alarm H1-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

88

 

Upper heating tube alarm H2-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

89

 

Upper heating tube alarm H2-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

90

 

Upper heating tube alarm H2-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

91

 

Upper heating tube alarm H2-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

92

 

Upper heating tube alarm H3-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

93

 

Upper heating tube alarm H3-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

94

 

Upper heating tube alarm H3-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

95

 

Upper heating tube alarm H3-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

 

No.

Alarm Name/Description

Corrective Action

 

96

 

Upper heating tube alarm H4-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

97

 

Upper heating tube alarm H4-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

98

 

Upper heating tube alarm H4-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

99

 

Upper heating tube alarm H4-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

100

 

Upper heating tube alarm H5-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

101

 

Upper heating tube alarm H5-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

102

 

Upper heating tube alarm H5-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

103

 

Upper heating tube alarm H5-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

104

 

Upper heating tube alarm H6-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

105

 

Lower heating tube alarm H6-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

106

 

Lower heating tube alarm H6-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

107

 

Lower heating tube alarm H6-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

108

 

Lower heating tube alarm H7-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

109

 

Lower heating tube alarm H7-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

110

 

Lower heating tube alarm H7-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

111

 

Lower heating tube alarm H7-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

112

 

Lower heating tube alarm H8-1

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

113

 

Lower heating tube alarm H8-2

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

 

No.

Alarm Name/Description

Corrective Action

 

114

 

Lower heating tube alarm H8-3

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

115

 

Lower heating tube alarm H8-4

1. Check the wiring is correct .

2.   Check if the heating tube is damaged

 

 

 

116

 

 

 

Safety do in work position

1.Check if the safety door is in work position 2.If it is reached, check whether the magnetic switch for detecting the work position of the safety door is on. If it is on, check the wiring; if not, adjust the magnetic switch until the light is on

3.Check if the magnetic switch is damaged

 

 

 

117

 

 

 

Lower tool lock not reached 1

1. Check if the lower tool lock 1 is in work position

2. Check if the magnetic switch position is correct (refer to red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

118

 

 

 

Lower tool lock not reached 2

1. Check if the lower tool lock 2 is in work position

2. Check if the magnetic switch position is correct (refer to red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

119

 

 

Lower tool locator in work position, please check the locator

1. Check if the lower tool locator is in work position

2. Check if the magnetic switch position is correct (refer to red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

120

 

 

Trolley not away from the machine, please check the tool detection

1.Pull the trolley away from the machine 2.Check the position of the inductive switch(refer to red line)

3. Check if the induction switch is damaged

4. Check the wiring

 

 

121

 

 

Upper tool lock left side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

No.

Alarm Name/Description

Corrective Action

 

 

122

 

 

Upper tool lock right side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

123

 

 

Upper tool home position setting fault

Value of upper tool home position shall be smaller than the upper tool hot melt position. Reset the upper tool home position to clear

the alarm

 

 

124

 

 

Lower tool home position setting fault

Value of lower tool home position shall be smaller than the lower tool hot melt position. Reset the lower tool home position to clear the

alarm

 

 

 

125

 

 

Upper tool auxiliary lock not in home position

1. Check if the upper auxiliary too lock is in home position

2. Check if the magnetic switch position is correct (refer to red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

126

 

 

Upper tool lock not reached 1

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

127

 

 

Upper tool lock not reached 2

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

128

 

 

Hot tool lock not reached 1

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

129

 

 

Hot tool lock not reached 2

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

No.

Alarm Name/Description

Corrective Action

 

 

130

 

 

Hot tool lock not reached 3

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

131

Automatic mode is on, please switch to manual mode

 

Switch to manual mode to clear the alarm

 

132

 

Hot tool detected, please check the detection point

1. Unload the hot tool

2.   Check if the proximity switch is damaged 3.Check the wiring

 

 

133

 

Upper tool lock is locked, upper tool not detected, please check the upper tool detection point

1. Adjust the position of the proximity switch so that the upper tool can be detected at the upper tool detection point

2.   Check if the proximity switch is damaged

3. Check the wiring

 

134

Upper tool lock is released, upper tool detection reached, please check the upper tool detection point

1. Unload the upper tool

2.   Check if the proximity switch is damaged 3.Check the wiring

 

 

135

 

Hot tool not detected, hot tool lock not released, please see the upper tool lock signal point

1. Check if the upper tool lock home position detection sensor and if the lock is home position

2. Check if the magnetic switch is damaged

3. Check the wiring

 

136

Hot tool not in home position, please move hot tool to home position

Move the hot tool back to home position, alarm will then be cleared

 

 

137

Upper tool harting plug not in home position, please move upper tool to home position

1. Move upper tool harting plug to home position

2. Check if the magnetic switch is damaged

3. Check the wiring

 

 

138

Hot tool harting plug not in home position, please move hot tool to home position

1. Move the hot tool harting plug to home position

2. Check if the magnetic switch is damaged

3. Check the wiring

 

139

Hot tool not in home position, please move hot tool to home position

Move the hot tool back to home position, alarm will then be cleared

 

140

Hot tool harting plug not in work

position, please move hot tool to work position

Move the hot tool back to home position, alarm will then be cleared

 

 

No.

Alarm Name/Description

Corrective Action

 

 

141

 

Hot tool lock not retracted, please check hot tool signal point

1.Check if the tot tool lock is in home position and if the the signal point position is correct 2.Check if the magnetic switch is damaged 3.Check the wiring

 

142

Hot tool not in home position, please move hot tool to home position

Move the hot tool back to home position, alarm will then be cleared

 

143

Upper tool not in home position, please reset upper tool

Move the upper tool to home position, alarm will then be cleared

 

144

Upper tool not in home position, please reset upper tool

Move the upper tool to home position, alarm will then be cleared

 

145

Lower tool not in home position, please reset lower tool

Move the lower tool to home position, alarm will then be cleared

 

 

 

146

 

 

Hot tool detection not reached, please hot tool signal point

1. Load hot tool

2.   Check if the hot tool can be detected at the position of proximity switch

3.   Check if the proximity switch is damaged 4.Check the wiring

 

147

Lower tool not in hot tool change position

Move the lower tool to hot tool change position and alarm will be cleared

 

148

 

Hot tool detection reached, please hot tool signal point

1.Check if the hot tool is unloaded 2.Check if the proximity switch is damaged 3.Check the wiring

 

149

Upper tool not in tool change position, please move upper tool to work position

Set the upper tool locating to upper tool change position and alarm will be cleared.

 

150

Lower tool not in upper tool change position, please move lower tool to work position

 

Set the lower tool locating to upper tool change position and alarm will be cleared.

 

151

 

Upper tool lock cylinder not in work position, please check signal point

1.Check upper tool lock is in work position 2.Check if the magnetic switch is damaged 3.Check the wiring

 

152

Upper tool not in tool change position, please move upper tool to work position

Set the upper tool locating to upper tool change position and alarm will be cleared.

 

153

Lower tool not in upper tool change position, please move lower tool to work position

 

Set the lower tool locating to upper tool change position and alarm will be cleared.

 

 

No.

Alarm Name/Description

Corrective Action

 

 

154

Upper auxiliary lock cylinder not in home position, please check signal point

1. Check if the upper tool lock is in work position

2. Check if the magnetic switch is damaged

3. Check the wiring

 

 

 

155

 

 

Lower tool harting plug not in home position

1. Move lower tool harting plug to home position

2. Check if the magnetic switch position is correct

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

156

 

 

Lower tool detection not detected, please check signal point

1. Check if the lower tool is loaded

2.   Check if the lower tool can be detected at the position of proximity switch

3.   Check if the proximity switch is damaged 4.Check the wiring

 

 

157

 

 

Lower tool lock cylinder not in home position

1.Check if the tool lock is reached 2.Check if the magnetic switch position is correct

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

158

 

 

Lower tool harting plug not in home position

1. Move lower tool harting plug to home position

2. Check if the magnetic switch position is correct

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

159

 

 

Lower tool lock not in work position, please check signal point

1.Check if the tool lock is in work position 2.Check if the magnetic switch position is correct

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

160

 

 

Hot tool detection left side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

161

 

 

Hot tool detection right side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

No.

Alarm Name/Description

Corrective Action

 

 

162

 

 

Hot tool detection rear side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

163

 

 

Lower tool detection right side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

164

 

 

Lower tool detection left side not detected

1. Check if the tool detection switch is damaged

2. Check the wiring

3. Adjust the position of tool detection sensor, lighten up the signal indicator

 

 

 

165

 

 

 

Upper tool lock not in home position

1.Check if the upper tool lock in home position 2.Check if the magnetic switch position changes (refer to the red line)

3.Check if the magnetic switch is damaged 4.Check the wiring

 

 

 

166

 

 

 

Hot tool lock not in home position

1.Check if the hot tool lock is in home position 2.Check if the magnetic switch position changes (refer to the red line)

3.Check if the magnetic switch is damaged 4.Check the wiring

 

 

 

167

 

 

Upper tool harting plug not in home position

1. Check if the upper tool hatring plug is in home position

2. Check if the magnetic switch position changes (refer to the red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

168

 

 

Hot tool harting plug not in home position

1. Check if the upper tool hatring plug is in home position

2. Check if the magnetic switch position changes (refer to the red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

169

Automatic tool change switch is OFF

Turn on the automatic tool change and alarm

will be cleared

 

170

 

Hot tool not in home position

Move the hot tool back to home position, alarm will then be cleared

 

 

No.

Alarm Name/Description

Corrective Action

 

 

171

 

Recipe detection is not matched with actual recipe

1. Check the connection of lower tool harting plug

2. Check if the recipe is correct

3. Check if the wiring in harting plug is correct

 

 

172

 

 

Lower part not unloaded

1.Unload the part from lower tool 2.Check if the part presence sensor is adjusted correctly

3. Check the wiring

4. Check the part presence sensor is damaged

 

 

 

173

 

 

Trolley not away from the machine, please check the tool detection

1.Pull the trolley away from the machine 2.Check if the position of detection switch changes (refer to the red line)

3.Check if the induction switch is damaged 4.Check the wiring

 

 

 

174

 

 

 

Upper tool not detected

1. Check if the upper tool nesting is matched with upper tool

2. Check if the position of proximity switch changes (refer to the red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

 

 

 

175

 

 

 

Hot tool detection not detected

1. Check if the hot tool nesting is matched with hot tool

2. Check if the position of proximity switch changes (refer to the red line)

3. Check if the magnetic switch is damaged

4. Check the wiring

176

Automatic tool change switch is OFF

Turn on the automatic tool change and alarm

will be cleared.

 

177

 

Guide column 1 not detected

Check the presence of guide column 1; if existed, then check the part presence sensor.

 

178

 

Guide column 2 not detected

Check the presence of guide column 2; if existed, then check the part presence sensor.

 

179

When the emergency stop safety relay is not reset or the door is not closed, the heating is closed

 

Reset the emergency stop safety replay or door safety replay and heat will be reset.

 

FAQ

ask us
anything

Electrical connection:

*The incorrect connection may cause the unintentional start or make the hot plate welding machine out of control during the operation

*The mix of the connection may reduce the lifetime of the hot plate plastic welding machine

*The incorrect connection may reduce the lifetime of the electrical components

Compressed air connection:

*Check if the compressed air hose is connected to the maintenance unit and if the position is fixed

*The manual switch valve must be opened for the operation

*Check if the pressure displayed is 6 bar

The dis function of safe prevention unit will cause life danger!

*Before the initial or daily operation or after a long time operation, the function of safe prevention unit should be checked

*Make sure all the safe prevention unit under the normal condition

Scroll to Top