| Pneumatic | Component and remove the system was not any action | The magnetic valve was not started | First check all magnetic valves, adjust air pressure per operation guide; if no abnormality, replace the magnetic valve. |
| Pneumatic | Component and remove the system was not any action | Interference with other parts | Click the reset button to reset all components. |
| Pneumatic | Component and remove the system was not any action | Pneumatic system has leakage | Check all air circuits and connections for leakage. |
| Pneumatic | Component and remove the system was not any action | Air pressure is too low | Adjust the pressure valve and use a pressure gauge to ensure normal air pressure. |
| Pneumatic | Component and remove the system was not any action | Magnetic valve or electrical connection fault | Manually test each valve. If no action, replace the magnetic valve. |
| Manual Mode | Hot plate cylinder not working | Select switch is not in manual mode | Check if the select switch is set to manual. |
| Manual Mode | Hot plate cylinder not working | Air tube or valve is damaged | Replace damaged parts. |
| Manual Mode | Hot plate cylinder not working | Upper/lower fixture not in reset state | Check reset magnetic switch status; adjust if not lit. |
| Manual Mode | Hot plate cylinder not working | No output from PLC | Check communication between touch screen and controller; replace controller if needed. |
| Manual Mode | Hot plate cylinder not working | Emergency stop is abnormal | Check emergency stop is released and circuit connection is normal. |
| Manual Mode | Upper/lower cool mould not working | Select switch is not in manual mode | Check if the select switch is set to manual. |
| Manual Mode | Upper/lower cool mould not working | Mechanical jam | Remove any jammed objects. |
| Manual Mode | Upper/lower cool mould not working | Hot plate slider not in position | Move hot plate slider to reset or weld position. |
| Manual Mode | Upper/lower cool mould not working | No output from PLC | Check communication between touch screen and controller; replace controller if needed. |
| Manual Mode | Upper/lower cool mould not working | Emergency stop is abnormal | Check emergency stop is released and circuit connection is normal. |
| Manual Mode | Upper/lower fixture not working | Select switch is not in manual mode | Check if the select switch is set to manual. |
| Manual Mode | Upper/lower fixture not working | Mechanical jam | Remove any jammed objects. |
| Manual Mode | Upper/lower fixture not working | Air tube or valve is damaged | Replace damaged parts. |
| Manual Mode | Upper/lower fixture not working | Fixture button failure | Check if fixture button is damaged and circuit connection is normal. |
| Manual Mode | Upper/lower fixture not working | No output from PLC | Check communication between touch screen and controller; replace controller if needed. |
| Auto Mode | hot plate welding Machine not running | Select switch is not in auto mode | Check if the select switch is set to auto. |
| Auto Mode | Position not reached | Upper/lower/slider magnetic switches not reset | Ensure all magnetic switches are in reset state. |
| Auto Mode | Safety curtain or emergency stop abnormal | Blocked light curtain or open emergency stop | Remove obstruction, check emergency stop and wiring. |
| Auto Mode | Start button not working | Start button damaged or wiring abnormal | Check and replace the start button and wiring if needed. |
| Auto Mode | PLC has no output | PLC controller fault | Replace the controller. |
| Auto Mode | Fixture does not activate | Fixture solenoid valve not energized | Ensure valve is powered; if not, hot plate welding machine won’t start. |
| Auto Mode | Slider does not move forward after start | Air pressure is too low | Adjust pressure valve to reach specified level. |
| Auto Mode | Slider cannot reach forward position | Magnetic switch not triggered | Check if slider reaches position; adjust magnetic switch if not lit. |
| Auto Mode | No timer after reaching hot position | Hot position magnetic switch not lit | Confirm upper/lower mold in position; adjust hot magnetic switch if needed. |
| Auto Mode | No solidification timing | Curing magnetic switch not lit | Confirm molds are closed; adjust curing switch position to activate. |
| Auto Mode | Fixture cylinder does not release after welding | Upper sucker still has suction | Replace small sucker or reduce upper sucker air pressure. |
| Auto Mode | Lower fixture cylinder not released | PLC program error | Modify PLC program; alternatively, press reset button to release cylinder. |